Installation Rules Paper 2: questions and answers
Paper 2 is the calculations paper. Below are four sample questions with worked answers, covering voltage drop, short-circuit current on AC and DC supplies, and a true or false question.
What Paper 2 covers
- Voltage drop, touch voltage, neutral current and load moment
- PSCC calculations for AC supplies and for DC (battery) supplies
- Conductors in conduit (Annexure F)
- Certification and verification, including the tests used to check an installation
- SANS 10142-1 Section 6 installation requirements and Section 8 verification and certification
- SANS 1973 requirements for low voltage switchgear and controlgear assemblies
See every module with page numbers in the Paper 2 study guide contents.
Four sample questions with worked answers
These questions use the same formulas and question styles as the study guide.
Question 1: voltage drop
A single-phase 230 V load draws 20 A through a 4 mm² copper cable. The total conductor length, phase and neutral together, is 60 m. Calculate the voltage drop and express it as a percentage of the supply voltage.
Answer: 6.6 V, which is 2.87 % of 230 V
Compare the percentage with the limit in SANS 10142-1. There are other four methods to calculate volage drop in the study guide.
Question 2: PSCC on an AC supply
A 315 kVA transformer, 400 V, has an impedance of 4 %. Ignoring the cable, calculate the three-phase prospective short-circuit current (PSCC) at the transformer terminals.
Answer: about 11.4 kA
In a full question you add the cable impedance to the transformer impedance before you divide.
Question 3: PSCC on a DC supply
A battery has 60 cells. Each cell has an internal resistance of 0.011 Ω. The battery link resistance is 0.1 Ω and the cable resistance is 0.05 Ω. Calculate the PSCC.
Answer: 169.4 A
Question 4: true or false
- For a balanced three-phase circuit, you multiply the voltage drop by √3.
- The single-phase PSCC is the supply voltage divided by the total impedance.
Answers: 1. True, 2. True
Which tables you will use
- Tables 6.3(b), 6.4(b) and 6.8 for installation requirements.
- Tables 6.22, 6.23 and 6.24 for conductors and conduit.
- Table 6.28 and Tables D.1, D.2 and D.3 for resistance, impedance and voltage drop values.
Your Paper 2 guide lists these as the important tables and shows which one each calculation needs.
What you get in the Paper 2 study pack
- The Paper 2 study guide, with Modules 1 to 10, worked examples and assignments
- Past exam papers with memos from 2005 to 2025
- An exam simulator that builds ten exam-style questions at a time
- Revision exercises and support when you are stuck
Not sure which package you need? Read the difference between Paper 1 and Paper 2, or look at the Paper 1 questions and answers if you are writing both.
Frequently asked questions
What does Paper 2 cover?
Paper 2 covers the calculations and installation requirements: voltage drop, PSCC on AC and DC supplies, conduit size, certification and verification, SANS 10142-1 Sections 6 and 8, and SANS 1973.
Which calculations come up most?
The guide has the most worked examples for voltage drop (29 examples) and PSCC (9 AC examples and 9 DC examples). Conduit size and verification calculations have worked examples too.
Which tables do I need?
Tables 6.3(b), 6.4(b), 6.8, 6.22, 6.23, 6.24, 6.28, D.1, D.2 and D.3 are listed in the guide as the important tables for Paper 2.
Can I try the exam simulator first?
Yes. The free Paper 2 simulator demo builds exam-style questions so you can see how it works before you buy.
Do I get past papers with memos?
Yes. The study pack includes past exam papers with memos from 2005 to 2025.
How long do I get access?
Your login is emailed instantly and access lasts 12 months from the date of purchase.